|
Tender Corrigendum :
|
| Tender Corrigendum | Cancellation of Tender | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Deadline has been changes from Oct 14 2025 12:00AM to Oct 29 2025 12:00AM Date Corrignedum | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Deadline has been changes from Oct 3 2025 12:00AM to Oct 14 2025 12:00AM Bid Submisssion Extension | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers | | Tender Corrigendum | Technical Corrigendum | | Tender Corrigendum Publication | Company Web Site - Internet | | Tender Corrigendum Document | Can be download by Subscribers |
|
|
Product Detail :
|
Request for Bids For Supply, Installation and Commissioning of Slaughter House Plant as per APEDA standard Request for Bids For Supply, Installation and Commissioning of Slaughter House Plant as per APEDA standard Request for Bids For Supply, Installation and Commissioning of Slaughter House Plant as per APEDA standard, Supply, Installation and Commissioning of Slaughter House Plant as per APEDA standard, Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete, Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete, Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB, Lift upto 1.50 M, Providing & erecting 4 Pole MCCB, 415 V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB Note 1)For use of 4 pole MCCBs in place of 3 pole MCCBs add 20% in rate of 3 pole MCCB. 2)In case of specialised application, MCCB used at incomer level shall be microprocessor based with LSIG (overload, short circuit, instantaneous, earth fault) inbuilt protection and shall have door mounted display to ensure close door operation; increase the rate by 20%, Supplying and fixing PVC synthetic elastomer electrically insulating mat with class C insulation conforming to IS 15652 – 2006 tested having 3mm thickness up to 33 kV, Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB, Providing fly ash brick masonry with conventional/ Indian Standard I.S. type bricks in cement mortar 16 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete, CEMENT Standard Consistancy, Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength, Soundness, Providing and erecting Heat shrinkable outdoor termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT, Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS 15652 – 2006 having 2 mm thickness up to 3.3 kV, Valves (FF-FV) .Non Return Valve (NRV). Supplying and erecting 200 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV R.A. Unit 1 / Each, Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete, Material Testing, 25.74 Providing and laying Cast in situ/Ready Mix cement concrete Mix-30 (M-30) of trap/ granite / quartzite/ gneiss metal for Reinforcement Cement Concrete (R.C.C.) slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 13 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with Supervisory Control and Data Acquisition (SCADA) enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade), Providing waterproofing in Water Closet (W.C.) and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 13 on vergin concrete slab with waterproofing compound @ 1Kilogram/per bag of cement laying brick bat coba of required thickness in cm 15 with waterproofing compound 1 Kilogram/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 13 with waterproofing compound 1 Kilogram/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete, Valves (FF-FV) .Gate / Wheel Valves (GV). Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF VL/GV R.A. Unit 1 / Each, Supplying, installing, testing and commissioning of 3 kWp ON-GRID Solar PV System / Plant consisting solar PV poly crystalline panel (335 Wp X 09 Nos
|
| Tender Detail : |
Request for Bids For Supply, Installation and Commissioning of Slaughter House Plant as per APEDA standard #*. Request for Bids For Supply, Installation and Commissioning of Slaughter House Plant as per APEDA standard |